1.0  INTRODUCTION

Star-delta starting is widespread in Europe, and was hardly every used in the united state unti1 the manufacturer of large centrifugal air conditioning units started using them. Since more and more buildings are becoming centrally air conditioned, this starting method has become more popular in the United States.

Star delta starting accomplishes reduced voltage by first connecting the motor leads into a star configuration for starting. The motor started in the star connection will receive approximately 58% of the normal voltage and develop approximately 83% torque.

Star delta motors are specially wound with SIX leads brought out to enable the winding to be connected either in star or in delta. When a star delta starter is energized, two contactors close, with one contactor connecting the winding in a star configuration and voltage. After a time delay, the star contactor opens (momentarily de-energizing the motor), and the third contactor closed to reconnect the motor to the lines with the windings connected in Delta. Since the leads of the moor are disconnected and then reconnected, the star – Delta starter system is inherently an open transition type.

The appeal of this starting method, as with the part winding voltage reducing equipment such as resistors and transformers. Star – Delta gives higher starting torque per line ampere than a part winding, with noise and vibration considerably less.

Star – Delta starters have the disadvantage of being open transition; however, closed transition; versions are available at additional cost. In closed transition, the motor windings are kept energized for the few cycles required to transfer the motor windings from star to Delta such starters are resistor bank – hence the additional cost. Stating three phase motor with star – Delta starting methods is generally more economical.

 

 

Get the Complete Project

This is a premium project material and the complete research project plus questionnaires and references can be gotten at an affordable rate of N3,000 for Nigerian clients and $8 for international clients.

Click here to Get this Complete Project Chapter 1-5

 

 

 

 

 

You can also check other Research Project here:

  1. Accounting Research Project
  2. Adult Education
  3. Agricultural Science
  4. Banking & Finance
  5. Biblical Theology & CRS
  6. Biblical Theology and CRS
  7. Biology Education
  8. Business Administration
  9. Computer Engineering Project
  10. Computer Science 2
  11. Criminology Research Project
  12. Early Childhood Education
  13. Economic Education
  14. Education Research Project
  15. Educational Administration and Planning Research Project
  16. English
  17. English Education
  18. Entrepreneurship
  19. Environmental Sciences Research Project
  20. Guidance and Counselling Research Project
  21. History Education
  22. Human Kinetics and Health Education
  23. Management
  24. Maritime and Transportation
  25. Marketing
  26. Marketing Research Project 2
  27. Mass Communication
  28. Mathematics Education
  29. Medical Biochemistry Project
  30. Organizational Behaviour

32    Other Projects pdf doc

  1. Political Science
  2. Psychology
  3. Public Administration
  4. Public Health Research Project
  5. More Research Project
  6. Transportation Management
  7. Nursing

Education

Essay 

 

 

Full Project – Construction of 3 phase star Delta starter panel for 15hp induction motor